35,320 research outputs found

    Resistive MSGC with double layered electrodes

    Full text link
    The first successful attempts to optimize the electric field in Resistive Microstrip Gas Chamber (RMSGC) using additional field shaping strips located inside the detector substrate are described.Comment: Presented at 13th RD51 Collaboration meeting, CERN, Febr. 201

    Further developments and tests of microstrip gas counters with resistive electrodes

    Full text link
    We present results from further tests of Microstrip Gas Counters (MSGCs) with resistive electrodes. The maim advantage of this detector is that it is spark-protected: in contrast to "classical" MSGCs with metallic electrodes, sparks in this new detector do not destroy its electrodes. As a consequence the MSGC with resistive electrodes is more reliable in operation which may open new avenues in applications. One of them which is under investigation now is the use of Resistive electrodes MSGC (R-MSGC) as photodetector in some particular designs of noble liquid dark matter detectors.Comment: Presented at the RD-51 mini-week at CERN, January 17, 201

    First Tests of Gaseous Detectors Made of a Resistive Mesh

    Full text link
    We describe here various detectors designs: GEM type, MICROMEGAStype, PPACtype as well as cascaded detectors made of a resistive mesh manufactured from a resistive Kapton foil, (20 microns thick, resistivity a few MOhm per square) by a laser drilling technique. As in any other micropattern detectors the maximum achievable gas gain of these detectors is restricted by the Raether limit, however, the resistive mesh makes them and the front end electronics fully spark protected. This approach could be an alternative or complimentary to the ongoing efforts in developing MICROMEGAS and GEMs with resistive anode readout plates and can be especially beneficial in the case of micropattern detectors combined with a micropixel-type integrated front end electronic

    An improved design of spark-protected microstrip gas counters (R-MSGC)

    Full text link
    We have developed microstrip gas counters manufactured on standard printed circuit board and having the following features: resistive cathode strips, thin (10 micron) metallic anode strips and electrodes protected against surface discharges by a Coverlay layer at their edges. These features allow the detector to operate at gas gains as high as can be achieve with the best microstrip gas counters manufactured on glass substrates. We believe that after further developments this type of detectors can compete in some applications with other micropattern detectors, for example MICROMEGAS.Comment: Presented at the 7th RD51 Collaboration meeting, CERN, April 201

    The mechanism for the electrooxidation of procarbazine pharmaceutical preparation in alkaline media and its mathematical description

    Full text link
    The mechanism for the electrooxidation of procarbazine in alkaline media has been proposed. The process is realized completely on the electrode surface and is adsorption-controlled. The oscillatory behavior in this case is more probable, than for neutral media and may be caused by influences of electrochemical oxidation and salt dissolution from the electrode surface
    corecore